Vacuum Pressure Impregnated - Kiln Dried After Treatment (KDAT) Lumber, Plywood, Timber, Shake Shingles, Architectural Millwork, Specialty Treatments
ASTM E84 CLASS "A"; UL 723 TYPE 1; NFPA 255; UBC 42-1

Classified FRT Exterior Lumber
ASTM E84 Class A - UL 723
Kiln Dried After Treatment (KDAT)
Flame Spread <10
Smoke Developed <200
KDAT 19
No increase in the Listed Classification
When subjected to the Standard Rain
test ASTM D2898

Classified FRT Exterior Plywood
ASTM E84 Class A - UL 723
Kiln Dried After Treatment (KDAT)
Flame Spread <5
Smoke Developed <100
KDAT 15
No increase in the Listed Classification
When subjected to the Standard Rain
test ASTM D2898

  (SWRI) UL 1256 (ASTM E84) LUMBER exterior/interior
  (SWRI) UL1256(ASTM E84)PLYWOOD exterior/interior
  (Maxim)ASTM E-84 Standard or D-3806 equivalency
  (Maxim)ASTM E-84 Standard or D-3806 equivalency
  (Maxim)ASTM E-84 Standard or D-3806 equivalency
  (Maxim)ASTM E-84 Standard or D-3806 equivalency
  (Universal Lab) ASTM E 84;UL723; NFPA255; UBC 42-1
Flame Spread <25 ; smoke generation <100

Flame Safe Fire Retardant Coatings

are compliance tested to meet the following fire safety and building code requirements:
ASTM E84 Class A, UL723 Type 1, NFPA 255, NFPA 703,UBC 42-1 for interior use and exterior use SWRI 1256 (ASTM E84) plywood; SWRI 1256 (ASTM E84) lumberd UL 723; UL 723 CANADA; SWRI ASTM E84
ASTM D2898 procedure exterior fire retardant plywood, exterior fire retardant lumber and timbers;
ASTM E108 for fire retardant coating wood, cedar and pine shake shingles Class B;
NFPA 701, FAR25.853 a &b (Federal Aviation Req.), Federal Standard 16CFR [FF4-72] (mattress ticking), Boston, NY- NJ Port Authority, Cal 1237.1, and the Cal Tech 117-F for fire retardant spray on coatings for fabrics and textiles;
International Maritime Organization Resolution A.753(18) & ASTM F1173-95 wet classification for plastic pipe
ASTM E162 & 662, Federal standard PPP-B-320, PPP-B-636 and PPP-B-640L fire retardant coating for corrugated packaging, cardboard box and paper industry; and
CAL Administrative Code, Title 19 Public Safety, Art. 3,Sec. 1264.3 spray on fire retardant coating for Christmas trees.

The credibility of Flame Safe’s fire retardant products is well documented by accredited 3rd party testing agencies, including Underwriter’s Laboratories (UL), Southwest Research Institute (SWRI), Universal Laboratories, United States Testing, Western Fire Center, Maxim Technologies-Southwestern Laboratories, U.S. Forestry Department, FEMA, Forestry Commission of New South Wales, Australia, European Institute for Fire Research, Ontario Research of Canada, and more.